Toshiba Elevator and Building Systems Corporation

TECHNOLOGY

TechnologyBIM parts for Singapore

CAD type:Autodesk® Revit® since 2018
ELCOSMO-Ⅲ
Counter
weight
Type Nos of
person
Capacity
(kg)
Speed
(m/min)
Cage - size
Internal (A×B)
(mm)
Door width
W
(mm)
Hoistway Size
(mm)
BIM
(3D)
Back P9-CO W 9 610 60/96/105/120/150 1400 x 1100 800 1850 x 1660 .RFA
900 2050 x 1660
P11-CO W 11 750 60/96/105/120/150 1400 x 1350 800 1850 x 1910 .RFA
900 2050 x 1910
P15-CO W 15 1000 60/96/105/120/150 1600 x 1550 900 2100 x 2110 .RFA
1000 2300 x 2110
1100 2500 x 2110
Side P9-CO D 9 610 60/96/105/120/150 1100 x 1400 800 1835 x 1725 .RFA
900 2020 x 1725
P11-CO D 11 750 60/96/105/120/150 1100 x 1700 800 1850 x 2000 .RFA
900 2020 x 2000
D2 800 1850 x 2150 .RFA
900 2020 x 2150
P14-CO D 14 950 60/96/105/120/150 1100 x 2100 800 1850 x 2400 .RFA
900 2020 x 2400
D2 800 1850 x 2550 .RFA
900 2020 x 2550
Back P13-CO W 13 900 180 1600 x 1400 900 2050 x 2050 .RFA
1000 2175 x 2050
P17-CO W 17 1150 60/96/105/120/150/180 1800 x 1500 1000 2250 x 2150 .RFA
1100 2400 x 2150
P18-CO W 18 1250 60/96/105/120/150/180 2000 x 1400 1100 2450 x 2050 .RFA
P19-CO W 19 1275 60/96/105/120/150/180 2000 x 1500 1100 2450 x 2150 .RFA
P22-CO W 22 1500 60/96/105/120/150/180 2000 x 1700 1100 2450 x 2350 .RFA
1200 2650 x 2350
P24-CO W 24 1600 60/96/105/120/
150/180
2100 x 1750 1200 2650 x 2400 .RFA
P28-CO W 28 1900 60/96/105/120/
150/180
2100 x 1950 1200 2650 x 2600 .RFA
Side P13-CO W 13 900 180 1600 x 1400 900 2400 x 1820 .RFA
1000 2450 x 1820
P17-CO W 17 1150 60/96/105/120/
150/180
1800 x 1500 1000 2600 x 1840 .RFA
1100 2650 x 1840
P17-2S D 17 1150 60/96/105/120/
150/180
1200 x 2300 1100 2030 x 2710 .RFA
P16-2S D2 16 1100 1200 x 2200 1100 2030 x 2870 .RFA
P22-2S D 22 1500 60/96/105/120/
150/180
1400 x 2400 1200 2230 x 2810 .RFA
P21-2S D2 21 1450 1400 x 2300 1200 2230 x 2970 .RFA
Back P13-CO W 13 900 210/240 1600 x 1400 900 2050 x 2150 .RFA
1000 2250 x 2150
1100 2450 x 2150
P15-CO W 15 1000 210/240 1600 x 1550 900 2050 x 2300 .RFA
1000 2250 x 2300
1100 2450 x 2300

*Notes:

  • ・DBL-5 is applied for door motor.
    (*Hoist-way dimensions will differ when DBL-6 is applied)
  • ・We will not guarantee if the data is used for other areas or country listed
  • ・Please contact us for any further questions

Please use this form for inquiries regarding BIM.
Contact us

SPACEL-Ⅲ
Counter
weight
Type Nos of
person
Capacity
(kg)
Speed
(m/min)
Cage - size
Internal (A×B)
(mm)
Door width
W
(mm)
Hoistway Size
(mm)
BIM
(3D)
Side P9-CO W 9 610 60/96/105/120 1400 x 1100 800 1985 x 1610 .RFA
900 2145 x 1610
D 1100 x 1400 800 1835 x 1725 .RFA
900 2020 x 1725
P11-CO W 11 750 60/96/105/120 1400 x 1350 800 2000 x 1720 .RFA
900 2100 x 1720
D 1100 x 1700 800 1850 x 2000 .RFA
900 2020 x 2000
D2 1100 x 1700 800 1850 x 2150 .RFA
900 2020 x 2150
P14-CO D 14 950 60/96/105/120 1100 x 2100 800 1850 x 2400 .RFA
900 2020 x 2400
D2 1100 x 2100 800 1850 x 2550 .RFA
900 2020 x 2550
P15-CO W 15 1000 1600 x 1550 900 2200 x 1920 .RFA
1000 2300 x 1920
1100 2500 x 1920
Back P17-CO W 17 1150 60/96/105/120 1800 x 1500 1000 2400 x 2150 .RFA
1100
P19-CO W 19 1275 60/96/105/120 2000 x 1500 1100 2600 x 2150 .RFA
P22-CO W 22 1500 60/96/105/120 2000 x 1700 1100 2650 x 2350 .RFA
1200
P24-CO W 24 1600 60/96/105/120 2100 x 1750 1200 2750 x 2400 .RFA
P28-CO W 28 1900 60/96/105/120 2100 x 1950 1200 2750 x 2600 .RFA
Side P17-CO W 17 1150 60/96/105/120 1800 x 1500 1000 2600 x 1840 .RFA
1100 2650 x 1840
P18-CO W 18 1250 60/96/105/120 2000 x 1400 1100 2800 x 1800 .RFA
P17-2S D 17 1150 60/96/105/120 1200 x 2300 1100 2050 x 2710 .RFA
P16-2S D2 16 1100 1200 x 2200 1100 2050 x 2870 .RFA
P19-CO W 19 1275 60/96/105/120 2000 x 1500 1100 2800 x 1840 .RFA
P22-CO W 22 1500 60/96/105/120 2000 x 1700 1100 2825 x 2050 .RFA
1200 2875 x 2050
P22-2S D 22 1500 60/96/105/120 1400 x 2400 1200 2275 x 2810 .RFA
P21-2S D2 21 1450 1400 x 2300 1200 2275 x 2970 .RFA
P24-CO W 24 1600 60/96/105/120 2100 x 1750 1200 2925 x 2100 .RFA
P28-CO W 28 1900 60/96/105/120 2100 x 1950 1200 2925 x 2300 .RFA

*Notes:

  • ・DBL-5 is applied for door motor.
    (*Hoist-way dimensions will differ when DBL-6 is applied)
  • ・We will not guarantee if the data is used for other areas or country listed
  • ・Please contact us for any further questions

Please use this form for inquiries regarding BIM.
Contact us

New ELBRIGHT
Counter
weight
Type Nos of
person
Capacity
(kg)
Speed
(m/min)
Cage - size
Internal (A×B)
(mm)
Door width
W
(mm)
Hoistway Size
(mm)
BIM
(3D)
Back P9 9 600 120/150/180/
210/240/300
1400 x 1150 800 1940 x 1910 .RFA
P13 13 900 120/150/180/
210/240/300
1600 x 1350 900 2100 x 2110 .RFA
P15 15 1000 120/150/180/
210/240/300
1600 x 1500 900 2100 x 2310 .RFA
P17 17 1150 120/150/180/
210/240/300
1800 x 1500 1000 2300 x 2260 .RFA
P20 20 1350 120/150/180/
210/240/300
2000 x 1550 1000 2500 x 2310 .RFA
P24 24 1600 120/150/180/
210/240/300
2000 x 1800 1100 2500 x 2560 .RFA
P27 27 1800 120/150/180/
210/240/300
2100 x 1900 1200 2700 x 2660 .RFA
P29 29 1970 120/150/180/
210/240/300
2100 x 2000 1200 2700 x 2760 .RFA

Please use this form for inquiries regarding BIM.
Contact us

Kindmover
Type Deg. BIM
(3D)
S1000 30 .RFA
S800 30 .RFA
S600 30 .RFA
S1000 35 .RFA
S800 35 .RFA
S600 35 .RFA

*Notes:

  • ・We will not guarantee if the data is used for other areas or country listed
  • ・Please contact us for any further questions

Please use this form for inquiries regarding BIM.
Contact us

Catalog Download Instruction manual Elevator Basics
ToTop