Moving WalkMoving WalkTOSHIBA Standard Type TC Series

The concept of Moving Walk
Through year of experience for escalator technology, "Moving Walk" has brought about enjoyable gliding comfort.
Toshiba Moving Walk carries passengers safely, rapidly and comfortably as the means of transportation for a new age.
Toshiba's moving walk has a power efficient driving system and pleasant riding quality with simple design, which produces a relaxed and easy feeling with an extensive prospect.
Variations
Slope type

Flat type

Basic specifications
Typical specification
Type | Step width (mm) |
Angle of inclination | Rated speed (m/min) |
Rated speed (m/min) |
Application truss height (mm) |
Motor capacity (kw) |
Heat generation (kJ/h) |
|
---|---|---|---|---|---|---|---|---|
S1000 | ARC-12°-SD |
1000 |
12° |
30 |
6000 |
3000 to 4220 |
5.5 |
3495 |
4247 to 5883 |
7.5 |
4765 |
||||||
5911 to 9015 |
Ask for Detail |
|||||||
S800 | 800 |
4800 |
3000 to 5550 |
5.5 |
3495 |
|||
5578 to 5594 |
7.5 |
4765 |
||||||
S1000 | ARC-0°-SD |
1000 |
0° |
6000 |
36310 or less |
5.5 |
3495 |
The above application table based on GB16899-2011.
* Moving walk has other than the above specificatons, such as those with a speed of 40m/min or an inclination not exceeding 12° degress, can also be supplied. For further details as well as the specifications other than the standard ones, please contact Toshiba.
General specification
Item | Interior panel | Optional Specification |
---|---|---|
Application | TC series moving walk |
|
Control type | Single speed |
Automatic operation with low speed and stop by stand-by mode (without poles type.) is optional specifications. |
Temperature | 0℃ or more, 40℃ or less |
|
Humidity | Monthly av. 90% or less |
|
Power supply | For main power: Three phase AC. 380V-50Hz |
Three phase AC. 380V-60Hz,AC.400V-50Hz, AC.415V-50Hz, AC.440V-50Hz |
For lighting: Single phase AC.220V-50Hz |
Single phase AC. 220V-60Hz,AC.230V-50Hz, AC.240V-50Hz |
|
Voltage tolerance for main power | ±10% or less in machine room terminal. |
|
Voltage unbalance factor | 5% or less |
|
Frequency tolerance | ±5% |
|
Voltage tolerance for lighting | ±5% or less in machine room terminal. |
|
Installation place | Sheltered indoor spot |
Outdoor type is not applicable |
Corrosive gas | Don’t exist |
* Note 2 |
Explosive gas | Don’t exist |
|
Dust | Excessive dust must not exist |
0.3 mg/m3 or less |
Influence salt | Don’t exist |
Quantity of sea salt particle NaCl 0.003mg/day/100cm2 or less |
Note 1: When supplying lighting and inspection source from power source, need a step-down transformer.
Note 2: SO3: 0.02mg/day/100cm2 or less, NO2: 0.02mg/100cm2 or less, Cl: 0.006mg/day/100cm2 or less, NH4+: 0.02mg/day/100cm2 or less.
Handrail
Selected the most suitable color from seven available color variations to match the building use and design concepts.

Operation panel
* Incluted Emergency stop button
Flat type

For left side of drive unit side.
Slope type

Upper floor